The Clinical Chemistry Journal Club allows readers to discuss key articles by using focused slides as teaching tools. Each month Clinical Chemistry posts the original article and slides online, and they are then distributed to individuals and university Journal Clubs.
Original Article: https://doi.org/10.1093/clinchem/hvag066
Slides: Download ppt
Webinar (on demand), available through November 30, 2027: https://myadlm.org/Education/All-Webinars/Webinars/2026/November/Long-term-storage-of-formalin-fixed-paraffin-embedded-tissues
Abstract
Background
High-quality formalin-fixed paraffin-embedded tissue (FFPET) is needed for next-generation sequencing (NGS) to identify clinically actionable tumor mutations. Long-term storage of FFPET may increase sequencing artifacts confounding interpretation. This study assesses the effects of long-term storage on NGS quality control (QC) metrics, variant calling, and tumor mutation burden (TMB), and tests the hypothesis that a DNA repair enzyme may aid in the analysis of stored FFPET.
Methods
Sequencing was performed on 281 FFPET (0–17 years old) using a large hybrid-capture NGS panel, and QC metrics were evaluated. Paired sequencing was performed, with and without DNA enzyme repair, on an additional 10 FFPET at time 0 (T0) and after storage for 2 years or 4 years. Sequencing quality metrics, variant calling, and TMB scores were compared.
Results
Multiple QC metrics, including sequencing read depth, declined with prolonged storage, particularly for samples stored ≥5 years. Even 2–4 years of storage introduced sequencing artifacts totaling 191 false-positive variants, as compared with 154 true-positive variants. Artifact variant types included deamination single-nucleotide variants (SNVs), nondeamination SNVs, and insertion/deletion variants, all of which were detected above 5% variant allele frequency. Four samples were TMB-low at baseline, but TMB was artifactually elevated in the stored sample. The storage-associated artifacts, including TMB, were largely restored by pretreatment with a DNA repair enzyme.
Conclusions
Long-term storage of FFPET resulted in reduced DNA quality and sequencing quality metrics, as well as many artifactual variants. FFPET stored for longer than 2 years may benefit from pretreatment with a DNA repair enzyme.
